Read every meter, inverter and charger live, from the grid connection to the last sub-meter

Talk to us
  • Sub-metering
  • Solar self-consumption
  • Peak demand alerts
  • Transformer monitoring

Applications

What you can build

The projects teams in the sector deliver most often once their devices are connected.

  • Solar self-consumption

    Compare PV yield, battery charge and site demand in real time, and see how much of your own generation you use.

  • Load curves and peak demand

    Watch quarter-hour demand against contracted power and get warned before a peak becomes an excess charge.

  • Sub-metering

    Meter every floor, line, tenant or machine, and split the bill by what each one actually used.

  • EV charging

    Track energy and power per charge point, and keep charging inside the capacity the site has left.

  • Substations and transformers

    Follow top oil temperature, load and LV feeders on distribution transformers, and spot overloads early.

  • Anomaly alerts

    Catch night base load, a failed PV string or a meter that stops reporting the moment it happens.

Why it matters

A demand peak should not wait for the invoice

Without live readings, a demand peak is a line on next month's invoice. With them, it is an alert while the quarter hour is still running.

Without data

30 days

until the bill shows it

  1. 08:00Compressors and ovens start together
  2. 08:15Quarter-hour demand passes the contracted power
  3. Day 30The invoice arrives with an excess power charge

With Thinger.io

4 min

from rising demand to load shed

  1. 08:02Demand reaches 92% of contracted power
  2. 08:03Alert reaches the plant engineer on call
  3. 08:06EV chargers throttled from the dashboard

In the field

From the main meter to the roof

The transformer, the main meter, the PV inverter and the EV chargers report together, so demand, generation and charging read on the same timeline.

Energy instrumentation

What gets connected

The meters, inverters and field devices already on site, with the ranges and interfaces your engineers work with.

Instrument catalogue · EnergySHEET EN-01 · REV A · N.T.S.
EM-301Three-phase energy meterFIG. 01

The billing-grade reference on every board: import, export and quality of supply per phase, read every few seconds instead of once a month.

Measures
kWh import / export · kW · kvar · V · A · PF · Hz per phase
Range
Direct to 100 A or CT /5 A, /1 A · MID B+D
Output
Modbus RTU (RS-485) · LoRaWAN variants
Install
Main LV boards, tenant and line sub-metering
CT-110Clamp-on current sensorFIG. 02

Clips around a live feeder without a shutdown and shows what a motor, compressor or HVAC unit really draws, hour by hour.

Measures
Real-time RMS current · cumulative energy · temp
Range
0-1000 A RMS · ±1% typical · 50/60 Hz
Output
LoRaWAN · split core, no wiring to the bus
Install
Feeders, motors, compressors, HVAC
MB-210M-Bus and pulse converterFIG. 03

Brings the heat, gas and water meters already in the plant room online, without replacing a single one.

Measures
Heat, gas, water and electricity meters · pulse counts
Range
Up to 10 wired M-Bus meters · reads down to 15 min
Output
LoRaWAN
Install
Plant rooms, district heating substations
PV-401PV string inverterFIG. 04

Shows what each array really produces, string by string, so a tripped string or a soiled row shows up the same day, not in the annual report.

Measures
AC power · daily yield · DC V and A per MPPT · fault codes
Range
Three-phase, 50-110 kW class · multiple MPPT
Output
Modbus TCP · SunSpec register maps
Install
Rooftop and ground-mounted PV
BS-501Battery storage systemFIG. 05

Follows the battery behind the meter: how full it is, how healthy, and whether it charges and discharges when the tariff says it should.

Measures
State of charge · state of health · charge / discharge kW
Range
SOC 0-100 % · cell temperature min / max
Output
Modbus TCP from BMS or hybrid inverter
Install
Behind the meter storage, PV sites
TR-601Distribution transformer monitorFIG. 06

Watches the secondary substation nobody visits: top oil temperature, load per phase and the door, before an overload turns into an outage.

Measures
Top oil °C · load current · LV feeders · door
Range
20/0.4 kV oil-immersed, 630 kVA · PT100 via 4-20 mA
Output
4G RTU · CT, 4-20 mA and digital inputs
Install
Secondary substations
EV-701EV chargerFIG. 07

Meters every charging session with the charger's own MID meter and lets the site cap charging current when the building load peaks.

Measures
Session kWh · kW · charger state · current limit
Range
22 kW AC · DC fast variants · built-in MID meter
Output
Modbus TCP, limit writable · OCPP stays with your operator
Install
Car parks, fleet depots
Field signals acceptedLORAWAN · MODBUS RTU · MODBUS TCP · M-BUS · PULSE · 4-20 MA
Integration Every interface on this sheet lands in thinger.io through LoRaWAN servers (The Things Stack, ChirpStack, LORIOT), Node-RED or Linux edge gateways, or native device connections. Several of these meter families have ready-made plugins in the Thinger.io Marketplace.
EN-01 · REV A · N.T.S.

EVERY KILOWATT, ACCOUNTED FOR

Live dashboard

See it in action

A live app built with the dashboard SDK, running on a Thinger.io demo server. It is read-only, so explore it freely.

ConnectingRead-only demo account

Loading the live dashboard…

The platform

How it works

Field devices connect to Thinger.io over standard protocols. There you manage every device, store its data and trigger alarms.

From meter to decision

Every meter, inverter and charger keeps its own protocol, and the platform closes the loop.

  • LoRaWAN meters and current clamps through The Things Stack, ChirpStack or LORIOT
  • Modbus RTU/TCP, M-Bus and pulse meters read at the edge with Node-RED or the Linux client
  • Readings stored in data buckets; rules raise alerts, call webhooks or send commands

One site or a whole portfolio

Energy programmes grow from one plant room to hundreds of buildings or a fleet of PV plants.

  • Provisioning a thousand meters works like provisioning one
  • Per-customer accounts and white label dashboards under your own brand
  • Cloud, private cloud or on premise, with the same features

Success stories

Proven in the field

Good to know

Frequently asked questions

What teams ask before a pilot, answered with the numbers they need.

Still have questions? Talk to us
Which meters, inverters and chargers can connect to Thinger.io?

Anything that exposes its readings over a standard interface. LoRaWAN energy meters, current clamps and pulse counters arrive through The Things Stack, ChirpStack or LORIOT, and the Thinger.io Marketplace already has plugins with payload decoders for several of them. Wi-Fi and cellular devices speak MQTT or HTTP directly.

Wired equipment is read at the edge. A small gateway running the Node-RED plugin or the Thinger.io Linux client polls Modbus RTU or TCP registers on meters, PV inverters, battery systems and EV chargers, and M-Bus converters bring heat, gas and water meters in with them. The device keeps working as before; the platform simply starts reading it.

What is sub-metering and why measure below the main meter?

The utility meter tells you how much the whole site used. Sub-meters on floors, production lines, tenants or large machines tell you where it went. That breakdown is the basis of any energy management system, including ISO 50001: you cannot improve a significant energy use you cannot see.

Sub-metering also turns energy into a cost each department or tenant can own. When the bill is split by measured use instead of square metres, consumption drops on its own. For tenant billing, pick meters with MID approval; for internal allocation and efficiency work, a well installed current clamp is often enough.

How does peak demand monitoring work?

Many electricity tariffs measure demand as the average power over a short integration period, commonly 15 minutes in Europe, and charge extra when it exceeds the contracted power. The peak is set by a few minutes of coincident loads, such as compressors, ovens, HVAC and EV chargers starting together.

With readings every few seconds, the platform projects the current quarter hour, compares it with the contracted power and raises an alarm while there is still time to act. A rule or an operator can then defer non-critical loads, for example throttling chargers or pausing water heaters, so the peak never lands on the invoice.

Can we monitor solar self-consumption and batteries?

Yes. Most PV inverters expose AC power, daily yield, string voltages and currents and fault codes over Modbus TCP, many following the SunSpec register maps, and hybrid inverters and battery systems add state of charge and charge or discharge power. A meter at the grid connection point completes the picture with import and export.

With those three flows in one data bucket, dashboards show self-consumption (the share of PV used on site), self-sufficiency (the share of demand covered by PV) and the yield of each string, so an underperforming string or a tripped inverter shows up the same day instead of at the annual review.

Can Thinger.io monitor substations and transformers?

Yes, as a monitoring layer. In a secondary substation, an RTU or gateway reads the top oil temperature probe, the transformer load through current transformers, LV feeder meters and door or fault contacts, and reports over 4G or the utility's own network. The platform stores the history, draws load and temperature trends and raises alarms on overloads, hot transformers or lost communications.

Protection stays where it belongs, in the relays and switchgear on site. Thinger.io adds visibility across many substations, so maintenance can be planned on measured load and temperature instead of fixed rounds.

Can we keep our existing SCADA, EMS or BMS?

Yes, and most projects do. Thinger.io exposes every stored reading through a REST API, pushes events through webhooks and exports data buckets to CSV, so measured data can feed an existing SCADA historian, energy management system, BMS or billing platform. The built-in Node-RED plugin bridges industrial protocols such as Modbus and OPC UA in both directions, so the platform adds the sites and meters your current tools do not reach without replacing them.

Should we run the platform in the cloud or on premise, and is it secure?

Both are common. Cloud instances start fast and need no server administration, which suits pilots, ESCOs and multi-site portfolios. Private cloud or fully on premise deployments keep metering data inside your own infrastructure, which some utilities and critical infrastructure policies require. Thinger.io runs identically in every mode, with EU data residency and managed backups available.

Thinger.io is an ISO 27001 certified company. Devices connect over authenticated, encrypted channels, with per-device certificates over mutual TLS where the hardware supports it, and users sign in with MFA or single sign-on (OIDC). White label branding lets an energy service company run the platform under its own name, with each customer's sites kept separate.

How much does an energy monitoring solution cost?

It depends on the number of sites and meters, the hardware already installed and the integration work, so most projects are quoted individually. Existing meters with Modbus or M-Bus outputs usually only need a gateway, which keeps the hardware cost low. On the platform side, our Private Cloud plans are published on the pricing page and start at 49 euros per month for a dedicated instance, which is usually enough to run a first pilot. Enterprise and on premise deployments are sized per project.

Next step

Ready to build your energy solution?

Tell us about your devices and your deployment, and we will map them to the platform. Or start on a free account and see it first.